Commercial electrical and life-safety compliance, for one fixed monthly fee.
MDL Compliance looks after the electrical and life-safety compliance of commercial buildings across East Anglia and London. Full audit-ready records. One named contact. Everything from EICRs to emergency lighting to legionella, either in-house or coordinated under one contract.
What you are responsible for
Every commercial property carries a rolling set of obligations: periodic fixed wire testing, monthly emergency lighting tests, six-monthly fire alarm inspections, PAT, legionella, gas, security and access control. And the records to prove each one.
The problem is rarely the legislation. It is chasing several contractors per site and keeping the evidence in one place.
| Obligation | Frequency |
|---|---|
| Fixed wire testing (EICR) | Up to 5-yearly |
| Emergency lighting function test | Monthly |
| Emergency lighting full-duration test | Annual |
| Fire alarm engineer inspection | 6-monthly |
| PAT, gas, oil, legionella | Risk-assessed / annual |
| Security, access control, door entry | Annual service |
Retainer plans
Published prices. Quoted on an actual site survey, not over the phone.
Essentials
Single small unit, shop or office
- Monthly emergency lighting function test
- Annual 3-hour discharge test
- Branded monthly logbook
- Annual EICR, pro-rated
Standard
Multi-unit site or business park
- Everything in Essentials
- Fire alarm scheduling
- PAT register
- Legionella risk assessment and monitoring
- Same-business-day priority response
Comprehensive
Larger sites needing multi-trade coordination
- Everything in Standard
- Gas Safe partner coordination
- Oil boiler servicing (coming soon)
- Quarterly client meeting
- Annual review for your insurer
Remedial works quoted separately. Out-of-hours emergency call-outs at our standard commercial rate. Trade partner labour passed through at cost plus a coordination fee.
What is covered
Delivered by Matthew, in-house
- Electrical inspection and testing, EICR
- Emergency lighting compliance (BS 5266-1)
- Fire safety compliance support
- Legionella risk assessment (WH001, ACoP L8)
- PAT testing
- Security systems, access control and door entry: installation and maintenance
- Water detection systems
- EV charger installation
Coordinated through approved partners
- Gas Safe inspection and boiler servicing
- Fire alarm engineer inspection (BAFE SP203)
- Fire extinguisher servicing (BAFE SP101)
- Police-response monitored intruder alarms (NSI or SSAIB approved installer)
- Sprinkler, BMS, HVAC, compressed air, steam systems
- Asbestos surveys (UKAS-accredited)
All partner work is performed under the MDL Compliance contract. One invoice. Partner credentials and insurance verified annually.
The logbook is the product
Most contractors send a single certificate once a year. We send a full branded logbook every month.
- Week 1 · Site visitFunction tests and visual inspection, recorded live.
- Week 1 · Logbook updatedPass, fail and limitations captured with photos.
- Week 2 · Remedials quotedAny flagged items quoted within 48 hours. You decide.
- Weeks 2 to 4 · WorksScheduled around your tenants and operations.
- Week 4 · Report sentLogbook PDF: what we did, what is open, what is next.
Who we work with
Commercial landlords
Owners of 5 to 15 units, industrial estates and business parks.
Managing agents and surveyors
A reliable, documented contractor for your panel.
Facilities managers
One number, one invoice, one person responsible for the records.
Questions we are asked
How often does a commercial building need an EICR?
IET guidance sets maximum intervals by type of use: five years for offices and shops, and shorter intervals for some uses such as industrial premises. The previous report may also recommend an earlier date. We schedule yours from the actual report.
What emergency lighting tests are required?
Under BS 5266-1, a short function test every month and a full rated-duration test every year, with results recorded in a logbook. Both are included in every retainer.
Do you work with managing agents?
Yes. We work as a panel contractor for managing agents and surveyors, with one logbook per site that you can share with landlords and insurers.
What happens when a test fails?
It is flagged in the logbook and quoted within 48 hours. You decide the scope and timing; we do not push work.
Which areas do you cover?
Suffolk and East Anglia, with selected sites in London.
Request a sample logbook
See exactly what you receive every month before you commit.
MDL Compliance and MDL Lettings are trading names of Suffolk Electrical Support Services Ltd, registered in England and Wales, company no. 15976685. Registered office: 4 Maltings Garth, Thurston, Bury St Edmunds, Suffolk IP31 3PP. Property Redress Scheme membership PRS059716. ICO registration ZC201617. Not VAT registered. Lettings fees and legal · Privacy notice